Slantwall Fans
Box
Fans
Cone Fans
Slantwall
Fans
Cumberland offers 36"
and 50" galvanized steel belt drive and direct drive slantwall fans to
efficiently and effectively maintain optimal environmental conditions. All
galvanized fans are constructed of heavy gauge, G-90 grade galvanized steel
and use totally enclosed "TEAO" motors designed for high efficiency and
continuous duty cycles. Galvanized fan propellers are aerodynamically
balanced for maximum airflow.
Box
Fans
Cumberland Box fans feature heavy duty galvanized steel housings, grill
guards, venturis and propellers. Offered in 36" (14" and 19" depth) or 50"
(21" and 25" depth) diameters, these fans are available in either direct or
belt drive models.
Cone Fans
Optional discharge
cones can boost fan output by as much as 10-15% greatly increasing
efficiency. Made of all galvanized steel, cones are available in easy to
ship and assemble four-piece segments for 36" and 50" models.
Fiberglass Fans

NEW! The Boss
Cone Fan
Cumberland's 52" fiberglass cone
fan is the newest generation of ventilation equipment. The Boss Fan was
designed for poultry facilities that desire high capacity and
efficiency. Choose from the more economical galvanized steel propeller
or the premium aluminum propeller. Both styles of propellers are
balanced for maximum airflow. Upon request, housings can be shipped in a
two-piece knockdown version, along with the four piece cone dramatically
reducing freight cost. Other features include vinyl coated guard,
stainless steel square tubing, and stainless steel hardware.
Komfort Kooler Systems
Cumberland can assist you in adapting the Komfort Kooler to most new and
existing production facilities.

Curtain
Machine Controllers
Cumberland's Curtain Controllers maintain precise control of the
environment in naturally ventilated buildings.

Expert 32
Ventilation Controller

|
Cumberland Expert 32 Specifications
|
Model
|
Description
|
|
MPV |
10 amp variable speed booster control (for controls w/ 1
var. speed) |
|
MPVV |
20 amp variable speed booster control (for controls w/ 2
var. stages) |
|
PC2-COM |
communication circuit board for TC4 controls when
interfacing w/ PC3-INT |
|
PC3-INT |
computer interface control w/ software, alarm, & display
|
|
PF-5 |
potentiometer feedback control w/ display (must be used
w/ a TC4 or TC5 series control) |
|
PF-5B |
potentiometer feedback control, multiple operation, up
to 8 per control |
|
TC1-1SD |
single stage on-off control w/ display |
|
TC1-C |
variable speed control w/o display |
|
TC1-CD |
variable speed control w/ display |
|
TC1-MFS |
manual variable speed control
|
|
TC1-NV |
natural ventilation control w/o display
|
|
TC5-12SD |
12 stage on-off control w/ display |
|
TC4-1CH |
chimney actuator control
|
|
TC5-1N4F1 |
power/natural ventilation combination control-1 heat, 1
var., 1 on-off, 1 curtain, 1 mist |
|
TC4-1V2S |
1 variable, 2 on-off stages w/ display |
|
TC4-1V3S |
1 variable, 3 on-off stages w/ display |
|
TC4-1VHB |
10 amp variable control for heat mats or lamps w/
display |
|
TC4-4M |
4 zone misting control w/ display |
|
TC4-NV2S |
natural ventilation control, w/ display and 2 on-off
stages |
|
TC4-NVP |
progressive natural ventilation controller
|
|
TC4-NVS |
natural ventilation control, w/ display and 1 on-off
stage |
|
TC4-T10 |
1 channel 24 hour timer w/ display |
|
TC4-T30 |
3 channel 25 hour timer w/ display |
|
TC4-T4 |
7 stage combination natural/tunnel ventilation
control w/ display
|
|
TC4-T5 |
11 stage combination natural/tunnel ventilation
control w/ display
|
|
TC4-1N6F |
power natural ventilation combination control 2 heat, 1
var., 1 on-off, 1 stage fan and 1 mist |
|
TC5-2V2SA |
2 var., 2 on-off stages, alarm stage, display, humidity
probe optional |
|
TC5-2V4SA |
2 var., 4 on-off stages, alarm stage, display, humidity
probe optional |
|
TC5-1V6SA |
1 var., 6 on-off stages, alarm stage, display, humidity
probe optional |
|
TC5-8SDA |
8 stage on-off, alarm stage, display, humidity probe
optional |
|
TC5-1V10SA |
1 var., 10 on-off stages, alarm stage, display, humidity
probe optional |
|
TC5-1N5FA |
power natural ventilation control, 1 var., 1 or 2 on-off
stages, 1 curtain, 1 timed mist, 2 heat-zone or cascade,
alarm, display, humidity probe optional |
|
TC5-1N8FA |
power natural ventilation control, 2 var., 1 on-off, 1
curtain, 1 timed mist, 3 heat- zone or cascade, alarm,
display, humidity probe optional |
|
TC5-T6A |
11 stage combination natural/tunnel power control
|
|
SP-2 |
static pressure control w/ alarm output |
|
CWMC-1 |
water monitoring control for poultry |
|
Expert 32 |
32 output control, alarm output, timers, tunnel curtain,
cooling, fan stages and heaters |
|
E100-A1092 |
Auto Air Sensor. Static pressure control w/ manual
override, 110V |
|
E100-A1093 |
Auto Air Sensor. Static pressure control w/ manual
override, 220V |
|
|
|